TAdvanced基因擴(kuò)增儀(PCR儀)
|
|
- 高效的熱模塊:高品質(zhì)合金樣品槽,表面有金色合金涂層,耐腐蝕,通過獨(dú)特的設(shè)計(jì)和電子控制技術(shù),實(shí)現(xiàn)銀質(zhì)樣品槽才能達(dá)到的高效傳熱效果和快速的升降溫速率,節(jié)省PCR擴(kuò)增時(shí)間
- 精準(zhǔn)的溫度控制:通過智能的溫度控制系統(tǒng)RAC實(shí)現(xiàn)快速的升降溫變化、優(yōu)異的溫度準(zhǔn)確性和均一性,以及高度的重復(fù)性,實(shí)際溫度與設(shè)定溫度相比,沒有溫度過沖或下沖的現(xiàn)象,以獲得最佳的擴(kuò)增效果
- 溫度梯度功能:對(duì)于新的模板或引物,可非常方便獲得最佳的退火溫度(TAdvanced 96 G)
- 線性溫度梯度工具(LGT):實(shí)現(xiàn)準(zhǔn)確的溫度梯度設(shè)置和控制,極大地方便了PCR反應(yīng)條件尤其是退火溫度的優(yōu)化(TAdvanced 96 G)
- 高性能智能熱蓋(HPSL):深凹的熱蓋設(shè)計(jì)可有效地將熱量控制在熱蓋內(nèi),防蒸發(fā)效果極佳,升溫快速,提供持續(xù)穩(wěn)定的溫度和壓力控制,結(jié)實(shí)耐用,熱蓋打開后會(huì)自動(dòng)停留在最適位置,方便樣品的取放
- 多功能:具有專門的恒溫孵育功能模塊,設(shè)置模塊溫度、熱蓋溫度和孵育時(shí)間,即可作為金屬孵育器使用,耐用性強(qiáng)
- 靜音技術(shù)(WQT):運(yùn)行時(shí)非常安靜,無噪聲,運(yùn)行時(shí)最大聲音不超過45 dB,為您提供舒適的工作環(huán)境
- 巧妙的散熱設(shè)計(jì):通過儀器后部和底部進(jìn)行高效散熱,儀器旁邊可放置其他儀器,節(jié)省實(shí)驗(yàn)室空間
- 先進(jìn)的用戶管理系統(tǒng)(AUM):靈活的多層級(jí)用戶管理系統(tǒng),每個(gè)用戶都可設(shè)定不同的個(gè)性化的使用權(quán)限
- 用戶特異性的快速啟動(dòng):通過程序預(yù)覽和快速啟動(dòng)功能,無需繁瑣的查找搜索,用戶即可快速啟動(dòng)各自曾使用過的程序
- 儀器自檢功能:系統(tǒng)可進(jìn)行自動(dòng)的檢測(cè)診斷,自動(dòng)記錄儀器使用過程中的狀態(tài),提供各種運(yùn)行和故障信息
- 舒適:超大的7英寸彩色觸摸屏,水晶屏幕,高清顯示,反應(yīng)靈敏,符合人體工程學(xué)的設(shè)計(jì),無反光,操作直觀方便
|
 |
New powerful electronics
|
The TAdvanced thermal cycler is based on a new technology which is, among other things, characterized by very powerful electronics. The new device thus offers superior heating and cooling rates that helps achieve ramping rates with a sample block made of aluminum which are normally seen only with the highest quality instruments using silver blocks. The new electronics include USB- and Ethernet-ports as communication interfaces and a 7'' color touch screen with completely redesigned, clearly structured user software. |
User specific quick start of programs
|
The intuitive software offers very straightforward programming and for GMP-regulated laboratories highly configurable user management, plus extensive tools for system diagnostics as well as documentation of PCR runs. To create PCR protocols the user can select between tabular or graphical programming. The user-specific quick start in combination with the program preview makes tedious searches for previously used PCR programs superfluous. |
Linear Gradient Tool
|
The TAdvanced thermal cycler is optionally available with gradient function for the optimization of new primer pairs. The linear gradient tool allows one to set the desired temperature difference between the columns or rows of the sample block, thus enabling users to exactly configure the temperature shape of the gradient. As another option, the unit can be equipped with a quick block exchange function. Overall, you can choose between five different types of block modules, including a high-end variant of a 96-well silver block with outstanding heating and cooling rates allied to extremely high temperature uniformity for maximum reproducibility of experiments. |
 |
TAdvanced基因擴(kuò)增儀(PCR儀)
|
|
High-Speed Thermal Block
|
The TAdvanced Thermal Cycler is available with different block formats. Optionally the instrument can be equipped with quick block exchange technology that allows easy exchange of block modules in a few seconds. All blocks are made of aluminum and offer high ramp rates for fast protocol running times. Additionally, to achieve ultimate performance, a 96 well block made of silver is available Due to its excellent heat conductivity silver equilibrates extremely quickly, thus providing maximum speed and temperature uniformity. To protect the valuable silver blocks against corrosion, the block surfaces are gold plated. |

 |
By the rubber sealing at the lid an encapsulated space is formed when the lid is closed. The closed room serves to improve the temperature uniformity of the sample block and avoids formation of condensed water at the final PCR cooling step. Furthermore all blocks are perfectly sealed to prevent condensed water from penetrating the Peltier elements underneath the sample block and other parts of the electronics. By the perfect sealing the Peltier elements are protected and the instruments life time is expanded. |
High Performance Smart Lid
|
The TAdvanced heated lid has been optimized to heat twice as fast as with older models and thus helps to shorten protocol run times. Moreover the heated lid serves for two additional essential functions: It prevents the formation of condensed water at the reaction tube portion located above the block surface level and it ensures reliable contact between samples and thermal block by applying constant pressure. By the integrated clutch mechanism the pressure applied to the reaction tubes is always same regardless of the plastic ware height. The combination of the heated lid shape and the reliable contact pressure ensure an even temperature distribution between samples thus significantly improves the temperature uniformity. |

 |
With one press on the front button, the lid gently swings open and arrests in its end position. By this mechanism the lid cannot fall down and the heated lid is out of the radius of action when the user is inserting tubes or plates. Thus the risk of injury by violent pressure or the risk of burn by hot surfaces is prevented. |
Space saving design
|
The TAdvanced thermal cycler is designed to occupy minimum space on your lab bench. With a footprint of 28 x 46 x 26 cm (WxDxH) the TAdvanced requires considerably less space than most other comparable instruments. |
 |
User specific quick start of programs
|
Many other thermal cyclers offer a so called “l(fā)atest program list”. In the latest program list a certain number of PCR programs is collected and offered for quick start. The list is typically ordered only by date and the user has to search for the desired program. In contrast the TAdvanced software creates a user specific list and only the latest programs started by the currently logged-in user are offered for quick start. Even a lab member does not use the instrument for a longer time the information on the latest programs started by this user will not get lost. |
For maximum convenience the TAdvanced software features additionally features the program preview. Before start of a program the protocol steps are summarized in a clearly arranged table by the program preview tool. The program preview therefore provides a comprehensive overview on the protocol structure without the need to access programming screens. The program preview is also available before quick start of programs. |
Linear Gradient Tool
|
For optimizing new primer pairs in a single run the TAdvanced optionally can be equipped with gradient function. Finding the best primer annealing temperature is crucial for the specificity and efficiency of PCR reactions. Often optimization of experiments is conducted only limited leading to unspecific byproducts or reduced PCR sensitivity. By using the gradient function new primer pairs with unknown annealing temperatures can be tested quickly and optimized in very short time. |
 |
For maximum convenience the TAdvanced offers the Linear Gradient Tool. For most other instruments the temperature difference from row to row or from column to column in a gradient step varies across the sample block. The TAdvanced Linear Gradient Tool offers to program gradient steps with a defined temperature increment between the columns or rows. The Linear Gradient Tool option allows the comfortable creation of gradient steps and the best annealing temperature can be easily transformed to a non-gradient protocol. |
Open system philosophy
|
The TAdvanced is an open system regarding consumables and reagents. Depending upon the sample block the system can be used with single tubes, strips or plates. PCR plates can be standard profile or low profile and they can be skirted, semi-skirted or non-skirted. The TAdvance can handle all kind of plates and the plastic ware be sealed with domed caps, flat caps, sealing foil or other technologies. Regardless of the used sealing method thanks to the HPSL technology always the same pressure is applied to the consumables serving for absolutely reproducible conditions. |
The TAdvanced Thermal Cycler is not limited to reagents from a specific vendor and can be used with any kind of polymerase. Regardless if isothermal-, hot start- or non-hot start polymerases are used, the TAdvanced will produce reliable results. E.g. by programming a pause step for the initial denaturation the system can be used for manual hot start applications. After inserting samples into the hot block the PCR protocol can be started just by pressing “continue”. |
Security for regulated environments
|
The software can manage up to 30 user accounts. By default three different user-levels are available: Administrator, user with generic rights and user with limited rights. However, in a comfortable menu the administrator can configure the settings for each user individually by activating or inactivating single rights. By the user administration tool in combination with the password protection of user accounts access to the instrument can be limited to authorized persons and unwanted modifications to the system settings and PCR protocols prevented. |
With each system start the TAdvanced performs an initial self-test and additionally the software offers an extended self-test that can be initiated by the user. The results of the extended self-test becomes are summarized in a protocol and are stored by the instrument. Additionally to the self-test functions the instruments creates and stores run-logfiles for each single run. For long-term storage run-logfiles and extended self-test protocols can be exported as proprietary file format. |
 |
TAdvanced基因擴(kuò)增儀的技術(shù)參數(shù)
|
|
儀器名稱
|
TAdvanced系列
|
|
|
|
|
樣品通量 |
96 x 0.2ml PCR管,96孔板,12 x 8聯(lián)管 |
60 x 0.5ml PCR管 |
384孔板 |
模塊材質(zhì) |
高品質(zhì)合金槽,表面有的金色合金涂層,耐腐蝕 |
銀質(zhì) |
高品質(zhì)合金槽,表面有的金色合金涂層,耐腐蝕 |
模塊涂層 |
特殊合金 |
鍍金 |
特殊合金 |
最大升溫速率 |
6.0℃ |
8.0℃ |
6.0℃ |
4.0℃ |
平均升溫速率 |
5.5℃ |
7.0℃ |
5.5℃ |
3.8℃ |
最大降溫速率 |
4.0℃ |
5.5℃ |
4.0℃ |
2.0℃ |
平均降溫速率 |
3.5℃ |
4.5℃ |
3.0℃ |
1.7℃ |
溫度梯度模式 |
--/12列不同溫度梯度控制 |
溫度梯度跨度 |
最大30℃/最小0.1℃ |
最大40℃/最小0.1℃ |
最大30℃/最小0.1℃ |
最大20℃/最小0.1℃ |
溫度梯度范圍 |
20-99℃ |
4-99℃ |
20-99℃ |
20-99℃ |
溫度均一性 |
95℃ |
±0.60℃ |
±0.50℃ |
±0.60℃@ |
±0.50℃ |
|
70℃ |
±0.30℃ |
±0.25℃ |
±0.30℃ |
±0.25℃ |
|
55℃ |
±0.20℃ |
±0.15℃ |
±0.20℃ |
±0.15℃ |
溫度準(zhǔn)確性 |
±0.1℃ |
模塊溫度范圍 |
3-99℃ |
熱蓋溫度范圍 |
30-110℃ |
熱蓋 |
深凹設(shè)計(jì)的高性能智能熱蓋(HPSL),防蒸發(fā)效果明顯好于普通熱蓋,提供持續(xù)穩(wěn)定的溫度和壓力控制 |
軟件 |
用戶特異性的程序快速啟動(dòng)功能:每個(gè)用戶可快速啟動(dòng)自己最近使用過的5個(gè)程序 |
程序運(yùn)行顯示方式可在表格式和圖形式之間方便切換 |
--/線性溫度梯度工具(LGT) |
具有儀器自檢功能,自動(dòng)生成維修信息日志文件(SINF) |
具有斷電自動(dòng)重啟功能 |
儀器升降溫速率可以調(diào)節(jié) |
可查看溫度梯度圖表 |
可通過網(wǎng)絡(luò)接口連接電腦進(jìn)行軟件升級(jí) |
三個(gè)層級(jí)的用戶管理權(quán)限設(shè)置 |
程序存儲(chǔ)能力 |
可設(shè)立30個(gè)用戶管理賬戶,可存儲(chǔ)350個(gè)PCR程序 |
顯示屏 |
超大的7英寸彩色觸摸屏,水晶屏幕,無反光 |
靜音技術(shù) |
超靜音運(yùn)行,最大運(yùn)行聲音不超過45dB |
接口 |
USB接口,網(wǎng)絡(luò)接口 |
常規(guī)指標(biāo) |
重量:15kg,尺寸:277 x 264 x 457mm (W x H x D),工作功率:850W |
|
 |
TAdvanced基因擴(kuò)增儀的產(chǎn)品信息
|
|
產(chǎn)品編號(hào)
|
產(chǎn)品描述
|
846-2-070-211 |
Biometra TAdvanced 96,96 well,0.2 ml tubes, plates, strips |
846-2-070-201 |
Biometra TAdvanced 96 G,96 well,0.2 ml tubes, plates, strips |
846-2-070-251 |
Biometra TAdvanced 96 S,96 well,0.2 ml tubes, plates, strips |
846-2-070-241 |
Biometra TAdvanced 96 SG,96 well,0.2 ml tubes, plates, strips |
846-2-070-210 |
Biometra TAdvanced 60,60 well,0.5 ml tubes |
846-2-070-200 |
Biometra TAdvanced 60 G,60 well,0.5 ml tubes |
846-2-070-224 |
Biometra TAdvanced 384,384 well,384 well plates |
846-2-070-214 |
Biometra TAdvanced 384 G,384 well,384 well plates |
|
|
846-070-231 |
Biometra TAdvanced Block Module 96,96 well,0.2 ml tubes, plates, strips |
846-070-221 |
Biometra TAdvanced Block Module 96 G,96 well,0.2 ml tubes, plates, strips |
846-070-271 |
Biometra TAdvanced Block Module 96 S,96 well,0.2 ml tubes, plates, strips |
846-070-261 |
Biometra TAdvanced Block Module 96 SG,96 well,0.2 ml tubes, plates, strips |
846-070-230 |
Biometra TAdvanced Block Module 60,60 well,0.5 ml tubes |
846-070-220 |
Biometra TAdvanced Block Module 60 G,60 well,0.5 ml tubes |
846-070-234 |
Biometra TAdvanced Block Module 384,384 well,384 well plates |
846-070-224 |
Biometra TAdvanced Block Module 384 G,384 well,384 well plates |
846-2-070-280 |
Biometra TAdvanced Base Unit w/o block |
|
 |
在線產(chǎn)品樣本(PDF格式) |
|